Skip to content

Hypervisors

Roles with access

Only administrators have access to this feature.

Hypervisor RAM bar

This feature is available from IsardVDI version v14.119.0 onwards.

The hypervisor table includes a RAM progress bar for each online hypervisor. This bar visually displays the amount of memory used relative to the total available.

Reading the individual bar:

  • Used and total memory are displayed in XGB/YGB format.
  • The progress bar changes color based on the usage level:
    • Green: Usage below 70%.
    • Orange: Usage between 70% and the configured minimum free memory threshold (min_free_mem_gb).
    • Red: Free memory has dropped below the min_free_mem_gb threshold. As a percentage, the threshold is (total − min_free_mem_gb) / total.
  • If the hypervisor has hugepages configured, additional information is displayed in the format (HP: used/totalGB).

Tip

When a hypervisor's available memory drops below min_free_mem_gb, the hypervisor stops accepting new desktops until memory is freed, and its row is highlighted with a light red background.

Note

If min_free_mem_gb is 0 (the default value), there is no reserve: the bar stays orange from 70% and only turns red at 100%.

Total RAM summary (Pool Totals):

When more than one hypervisor is online, a summary panel is displayed at the top of the table with the aggregated totals for all hypervisors:

  • RAM Used / Total / Free: Combined used, total and free memory across all online hypervisors.
  • Combined progress bar: Displays the total usage percentage with a bar divided into two parts:
    • Used zone: color ranges from gray to red based on the percentage.
    • Free zone: green color.
  • VMs: Total number of virtual desktops started across all hypervisors.
  • HP (Hugepages): If any hypervisor has hugepages, displays the total used/available.

Hypervisor CPU bar

The CPU column shows the hypervisor's cores and threads (Nc/Mth) and a bar with the CPU usage percentage of the physical server.

How it is calculated: it is the last-minute average of the CPU time in user mode, kernel mode and I/O wait (iowait), adding up all the host's threads.

Colors:

  • Green: Usage below 20%.
  • Orange: Usage between 20% and 40%.
  • Red: Usage from 40%.

The CPU colors are only indicative

The thresholds are deliberately conservative, so that any increase in load is noticed right away. An orange bar does not mean that CPU is lacking. Unlike RAM, no CPU threshold prevents desktops from starting: the balancer only sends new desktops to the hypervisor with the most free CPU.

It is worth reviewing capacity if the bar stays red in a sustained way and, at the same time, users notice slowness on their desktops.

Actions button

This feature is available from IsardVDI version v14.119.0 onwards.

The hypervisor table includes a hidden quick actions column that can be displayed by clicking the Actions button in the table's top button bar.

When enabled, an additional column is displayed with the following buttons for each hypervisor:

Button Icon Description
Forced Enables or disables the "Only Forced" mode. When enabled, the hypervisor only starts desktops that have this specific hypervisor forced.
GPU Enables or disables the "Only GPU" mode. When enabled, the hypervisor only starts desktops that require GPU resources.
Orch Adds or removes the hypervisor from orchestrator management. The orchestrator controls the automatic power on and off of hypervisors based on demand.
On/Off Enables or disables the hypervisor. Disabling a hypervisor managed by the orchestrator also removes it from automatic management.

Warning

When disabling a hypervisor that is managed by the orchestrator, a notice is displayed indicating that the action will also remove the hypervisor from orchestrator management.

The detail view of each hypervisor (expanding a row with the icon ) has the same actions under the names Enable/Disable, Only forced, GPU only and Orchestrator.

In addition to these buttons, the detail view includes Delete, Edit and Stop all domains.

Orchestrator management

The orchestrator automatically powers hypervisors on and off based on demand. This way, the running fleet grows and shrinks with the load, instead of keeping all hypervisors permanently powered on.

On the Hypervisors page, the Orchestrator Managed Hypervisors panel contains everything related to this automation:

  • An Orchestrator enabled switch that activates or deactivates all automation for the installation. While it is disabled, no hypervisor is powered on or off automatically; each hypervisor keeps its current state.
  • The list of hypervisors currently under orchestrator management, that is, those that the orchestrator can power on or off.

A hypervisor enters or leaves this list through the per-hypervisor Orch action, described in the "Actions button" section. The Orchestrator enabled switch then controls automation globally, above the individual membership of each hypervisor.

Global switch

Disabling Orchestrator enabled immediately stops all automatic power management. Hypervisors that are already powered on remain on, and those that are off remain off, until the orchestrator is enabled again or an administrator changes them manually.

Hypervisor types

IsardVDI supports different hypervisor configurations based on the deployment architecture and the video traffic routing requirements. Understanding these types is essential for proper network configuration and performance optimization.

Hypervisor type

The hypervisor type includes integrated video broker services that allow direct client connections to the hypervisor for desktop streaming:

  • Integrated video services: Includes the isard-video broker to manage client video connections.
  • Direct client access: Clients connect directly to the hypervisor for video and screen traffic.
  • Self-contained solution: Complete hypervisor solution with integrated video broker capabilities.
  • Let's Encrypt support: Can generate its own SSL certificates for secure video connections.
  • Optimal performance: Eliminates the video broker overhead by serving clients directly.

Network characteristics:

  • Video traffic flows directly from clients to the hypervisor.
  • Reduces network latency and the load on the central broker.
  • Each hypervisor manages its own video certificates and broker.

Hypervisor-Standalone type

The hypervisor-standalone type operates without integrated video services, relying on a central video broker:

  • No integrated video broker: Does not include the isard-video service.
  • Centralized video routing: All video traffic is redirected through the main IsardVDI video service.
  • Simplified deployment: Minimal hypervisor footprint focused on running virtual machines.
  • Central management: Video certificates and broker configuration managed centrally.
  • Scalable architecture: Ideal for large deployments with many hypervisors.

Network characteristics:

  • Video traffic flow: Client → IsardVDI Central → Hypervisor-Standalone.
  • Requires configuring the VIDEO_HYPERVISOR_HOSTNAMES variable on the central IsardVDI server.
  • Requires TCP ports 5900-7899 to be open on the hypervisor-standalone for video broker access.
  • The central broker handles all SSL termination and video routing.
  • The hypervisor only requires outbound connectivity to the central services.

Operational modes

Regardless of the type, hypervisors can operate in different functional modes:

Pure hypervisor

When editing or creating a hypervisor, you can check whether it will only act as a hypervisor. In this mode, IsardVDI uses the server exclusively to run virtual desktops. This server does not handle virtual disk operations.

Pure disk operations

In this mode, the server is used exclusively to handle virtual desktop disk operations.

Mixed hypervisor + disk operations

This mode uses the server both to run virtual desktops and to handle virtual disk operations.

VPN tunneling modes

Note

The VPN tunneling mode is an installation-wide setting established in isardvdi.cfg (more information in the "Configuration" section below), not a per-hypervisor option.

IsardVDI supports two different VPN tunneling modes, which lets administrators choose the most suitable network configuration for the whole installation based on their infrastructure requirements:

WireGuard + Geneve (Default)

This is the default and recommended tunneling mode, which provides:

  • Full VPN encryption: All traffic between the hypervisor and the IsardVDI main server is encrypted using WireGuard.
  • Secure remote connections: Ideal for hypervisors located on different networks or over the internet.
  • Automatic Geneve tunnel configuration: Creates overlay networks for virtual desktop traffic.
  • High security: Best option when hypervisors are on untrusted networks.

Use cases:

  • Hypervisors in remote locations.
  • External hypervisors over the internet.
  • Multi-site deployments.
  • When maximum security is required.

Geneve only

This mode uses only Geneve tunneling without WireGuard encryption:

  • Direct network connectivity: Assumes that hypervisors can reach the main server directly.
  • Lower overhead: Reduces encryption overhead for better performance.
  • Simplified networking: Easier to troubleshoot and monitor.
  • Local deployments: Ideal for trusted local networks.

Use cases:

  • Hypervisors in the same data center.
  • Trusted local network environments.
  • High-performance requirements with minimal overhead.
  • Networks where encryption is handled at the infrastructure level.

Configuration

The VPN tunneling mode is an installation-wide setting, not a per-hypervisor option. There is no control in the per-hypervisor web form to choose the tunneling mode. Instead, it is determined globally by the GENEVE_ONLY_INFRA key in isardvdi.cfg:

  • GENEVE_ONLY_INFRA=false (default): WireGuard + Geneve tunneling.
  • GENEVE_ONLY_INFRA=true: Geneve only (direct Geneve, no WireGuard; requires an internal/trusted network).

This is a systems-level setting: change it in isardvdi.cfg and regenerate the deployment (./build.sh). All hypervisors in the installation use the mode derived from this value (the API stores the resulting tunneling_mode per hypervisor so that the isard-vpn container knows which mode to use, but the value comes from the global GENEVE_ONLY_INFRA setting). The details are in the systems manual and in isardvdi.cfg.example.

Important considerations:

Network requirements

Ports required per tunneling mode:

WireGuard + Geneve mode: - 4443 UDP: WireGuard tunnel from the hypervisor to isard-vpn (configurable via WG_HYPERS_PORT). - 2022 TCP: SSH control from isard-engine to the hypervisor. - 5900-7899 TCP: Video/screen traffic to the hypervisor. - 6379 TCP: Redis tasks from the hypervisor to isard-storage.

Geneve only mode: - 6081 UDP: Direct Geneve tunnel from the hypervisor to isard-vpn (standard Geneve port). - 2022 TCP: SSH control from isard-engine to the hypervisor. - 5900-7899 TCP: Video/screen traffic to the hypervisor. - 6379 TCP: Redis tasks from the hypervisor to isard-storage.

Port configuration

  • The WireGuard port can be customized via WG_HYPERS_PORT in isardvdi.cfg (default: 4443).
  • Geneve uses the standard UDP port 6081 for tunnel encapsulation.
  • All ports must be reachable between the hypervisor and the IsardVDI server.
  • The network infrastructure must support the chosen tunneling mode.

Performance vs. security

WireGuard + Geneve gives maximum security and Geneve only, maximum performance on trusted networks.

Technical details

  • Geneve tunneling: Creates overlay networks using UDP encapsulation (port 6081).
  • WireGuard encryption: Provides next-generation VPN encryption when enabled (port 4443 by default).
  • Automatic configuration: IsardVDI automatically configures the chosen tunneling mode.
  • OVS integration: Both modes integrate seamlessly with Open vSwitch for network management.

Port requirements summary

Traffic type WireGuard+Geneve Geneve only Direction Open/Redirect on Description
VPN tunnel 4443/UDP 6081/UDP Hypervisor → IsardVDI IsardVDI server (inbound) Primary tunnel connection.
SSH control 2022/TCP 2022/TCP IsardVDI → Hypervisor Hypervisor (inbound) Engine management.
Video/Screen 5900-7899/TCP 5900-7899/TCP Client → Hypervisor Standalone hypervisor only Desktop streaming.
Storage tasks 6379/TCP 6379/TCP Hypervisor (isard-storage) → IsardVDI IsardVDI server (inbound) Redis/storage operations.

Firewall and port forwarding configuration

For WireGuard + Geneve mode:

# On the IsardVDI server - redirect inbound connections to specific container IPs
iptables -t nat -A PREROUTING -p udp --dport 4443 -j DNAT --to-destination 172.31.255.23:4443
# Or using firewalld:
firewall-cmd --add-forward-port=port=4443:proto=udp:toaddr=172.31.255.23:toport=4443 --permanent

# On the hypervisor - redirect inbound SSH connections to the hypervisor container
iptables -t nat -A PREROUTING -p tcp --dport 2022 -j DNAT --to-destination 172.31.255.17:2022
# Or using firewalld:
firewall-cmd --add-forward-port=port=2022:proto=tcp:toaddr=172.31.255.17:toport=2022 --permanent

For Geneve only mode:

# On the IsardVDI server - redirect inbound connections to specific container IPs
iptables -t nat -A PREROUTING -p udp --dport 6081 -j DNAT --to-destination 172.31.255.23:6081
iptables -t nat -A PREROUTING -p tcp --dport 6379 -j DNAT --to-destination 172.31.255.12:6379
# Or using firewalld:
firewall-cmd --add-forward-port=port=6081:proto=udp:toaddr=172.31.255.23:toport=6081 --permanent
firewall-cmd --add-forward-port=port=6379:proto=tcp:toaddr=172.31.255.12:toport=6379 --permanent

# On the hypervisor - redirect inbound SSH connections to the hypervisor container
iptables -t nat -A PREROUTING -p tcp --dport 2022 -j DNAT --to-destination 172.31.255.17:2022
# Or using firewalld:
firewall-cmd --add-forward-port=port=2022:proto=tcp:toaddr=172.31.255.17:toport=2022 --permanent

Docker port forwarding details

These ports must be redirected to the specific IP addresses of the Docker containers on the IsardVDI network:

On the IsardVDI server side (default network: 172.31.255.0/24): - WireGuard (4443/UDP) → Redirect to 172.31.255.23:4443 (isard-vpn container). - Geneve (6081/UDP) → Redirect to 172.31.255.23:6081 (isard-vpn container). - Redis (6379/TCP) → Redirect to 172.31.255.12:6379 (isard-redis container, if the hypervisor also has isard-storage).

On the hypervisor side (default network: 172.31.255.0/24): - SSH (2022/TCP) → Redirect to 172.31.255.17:2022 (isard-hypervisor container, where sshd listens on port 2022).

Additional ports for hypervisor-standalone (video/screen access):

# On the hypervisor-standalone - redirect video/screen ports for direct client access
iptables -t nat -A PREROUTING -p tcp --dport 5900:7899 -j DNAT --to-destination 172.31.255.17:5900-7899
# Or using firewalld (example for specific ports):
firewall-cmd --add-forward-port=port=5900:proto=tcp:toaddr=172.31.255.17:toport=5900 --permanent
# ... repeat for the 5900-7899 range as needed

Notes: - These IPs can be configured via the DOCKER_NET environment variable (default: 172.31.255). - Hypervisors only need outbound connections allowed to establish the tunnel. - docker network inspect isard-network shows the current container IPs. - The router/firewall must redirect external ports to these internal container IPs.

Video proxy configuration for hypervisor-standalone

When using the hypervisor-standalone type, the video proxy must be configured:

In isardvdi.cfg on the IsardVDI server:

# Allow hypervisor-standalone hosts to be proxied for video traffic
# Note: if the main IsardVDI is an all-in-one type with a hypervisor,
#       the isard-hypervisor name must also be added to the list.
VIDEO_HYPERVISOR_HOSTNAMES=hypervisor1.example.com,hypervisor2.example.com
VIDEO_HYPERVISOR_PORTS=5900-7899

Security considerations: - Only add trusted hypervisor hostnames to VIDEO_HYPERVISOR_HOSTNAMES. - This setting controls which hypervisors the IsardVDI video proxy accepts connections for. - Comma-separated list of hostnames as seen from the IsardVDI server.

External hypervisors

An external hypervisor is a server that only runs the isard-hypervisor container (and its accompanying services) and connects to an IsardVDI installation that is already working. The only supported method is to deploy it with the IsardVDI containers, with the hypervisor or hypervisor-standalone flavour (more information in the "Hypervisor types" section of this page).

On startup, the container registers itself with the API: it creates or updates its entry in Hypervisors, receives the isard-engine public key and the viewer certificates and, once it has passed the checks, enables itself. There is no need to copy SSH keys or certificates by hand. The process is described below, in the "Hypervisor self-registration flow and VPN configuration" section.

Install the hypervisor

  1. On the server that will act as the hypervisor, install Docker and clone the IsardVDI repository, just as for a complete installation.
  2. Copy isardvdi.cfg.example to isardvdi.cfg and configure at least these variables:

    FLAVOUR=hypervisor            # or hypervisor-standalone
    DOMAIN=<hypervisor name or IP>
    HYPER_ID=<unique hypervisor identifier>
    API_DOMAIN=<main API address reachable from the hypervisor>
    STATIC_DOMAIN=<public domain of the main installation>
    VPN_DOMAIN=<isard-vpn address reachable from the hypervisor>
    

    The secrets (for example, API_HYPERVISORS_SECRET) must be the same as those of the main installation. With the hypervisor flavour, VIDEO_DOMAIN is the name clients use to reach this hypervisor's viewers, and it is used to generate their certificates. The complete examples for each architecture are in the systems manual, in Infrastructure concepts.

  3. Generate the compose file and start the containers:

    ./build.sh
    docker compose pull
    docker compose up -d
    

    ./build.sh generates docker-compose.yml from isardvdi.cfg. If the folder has several isardvdi.<name>.cfg files, you can choose one by passing it as an argument (./build.sh isardvdi.<name>.cfg), and the generated file is docker-compose.<name>.yml.

  4. Check that the hypervisor appears in Infrastructure → Hypervisors and that it changes to the Online status. Registration errors can be checked with docker logs isard-hypervisor and, on the main server, with docker logs isard-engine.

Ports

The sshd of the isard-hypervisor container listens on port 2022, so the server's port 22 remains free for SSH access to the host. If INFRASTRUCTURE_HOST_IP is set in the hypervisor's isardvdi.cfg, the compose file publishes 2022/TCP and the tunnel port (WG_HYPERS_PORT, 4443/UDP by default) on that IP. Otherwise, they must be redirected with the firewall, as explained in the "Port requirements summary" section.

Add or edit a hypervisor from the web interface

Normally the hypervisor does not need to be created by hand, because it registers itself. The form is used to review or correct the data of an already registered hypervisor (Edit button in the details, with the hypervisor disabled) or to add one manually. To create one, in Infrastructure → Hypervisors click the Add new button:

A window opens with the hypervisor fields. The Name field is its identifier and can have any value; the other fields must match the remote hypervisor:

  • Hostname: IP or DNS name with which the IsardVDI installation reaches the hypervisor. It can be an internal network between both servers.
  • User and SSH Port: root and 2022, the port of the container's sshd.
  • Disk operations and Hypervisor: enabling both options is recommended (more information in the "Operational modes" section).
  • Web host: IP or name of the web installation.
  • Video proxy host (squid/websockify): IP or name reachable from outside to access the hypervisor's viewers (ports 80 and 443 by default).
  • Hypervisor hostname from video proxy: isard-hypervisor, which is the default container name.
  • Pools: hypervisor pool it belongs to (more information in Hypervisor pools).

If the connection fails, disable the hypervisor, correct the parameters and enable it again: isard-engine verifies the connection again. The error message can be seen in the hypervisor details (+ icon of the row).

Manual SSH access

isard-engine includes the /add-hypervisor.sh script, which copies the engine's key to a hypervisor with a username and password and checks that libvirt responds there. With self-registration it is not needed; it is only useful to diagnose SSH access:

docker exec -e HYPERVISOR=<IP|DNS> -e PASSWORD=<root password> -e PORT=2022 isard-engine bash -c '/add-hypervisor.sh'; history -d $((HISTCMD-1))

PORT (22 by default) and USER (root by default) are optional. The final history -d prevents the password from staying in the shell history.

To remove a hypervisor, for example the one an all-in-one installation brings by default, disable it and delete it from its details with Delete. If it stays in the Deleting status, the button changes to Force delete.

VLANs on the hypervisor

To connect a trunk interface with VLAN definitions inside the hypervisor, configure (and uncomment) these variables in the hypervisor's isardvdi.cfg and run ./build.sh again:

  • HYPERVISOR_HOST_TRUNK_INTERFACE: name of the trunk interface as seen on the host. For example: eth1.

    If HYPERVISOR_STATIC_VLANS is not configured, the hypervisor automatically detects VLANs for 260 seconds each time the isard-hypervisor container starts. That is why it is better to define the VLANs known to be on the trunk.

  • HYPERVISOR_STATIC_VLANS: comma-separated list of VLAN numbers. It disables automatic detection.

The hypervisor sends the VLANs found to the API, which creates them as vXXX interfaces (name «Vlan XXX»), where XXX is the VLAN number. No direct database access is needed. Only administrators can use the new interfaces: decide who else can use them in Resources.

Note

The host interface must be in promiscuous mode: ip link set dev ethX promisc on. If the isard-hypervisor container was already running, stop it and start it again.

Infrastructure concepts

When adding an external hypervisor, consider (and configure as needed) the following:

  • Disk path: By default, disks are stored in /opt/isard. You do not need to create this folder, but it is recommended to mount fast I/O storage (such as an NVMe disk) at this path.

  • Network performance: If a NAS is used, a fast network is required. The recommended network speed is greater than 10 Gbps.

Disk performance

Since different paths are used for bases, templates and group disks, performance can be improved by mounting different NVMe storage disks at each path:

  • /opt/isard/bases: This is where the created base images reside. Generally, these disk images are used as a base for many templates and user (group) disks. Therefore, the storage must provide the fastest possible read access.

  • /opt/isard/templates: Templates are also used as main disks for several user (group) disks. It is recommended to use a disk with fast read access.

  • /opt/isard/groups: Running desktops reside here. Many simultaneous I/O operations happen at this path, so the storage must provide the highest possible number of IOPS. NVMe disks (or even NVMe RAIDs) offer the best performance.

Network performance

The storage network between the hypervisors and the NAS storage servers must be at least 10 Gbps. All hypervisors must mount the storage at the /isard path, and this mount must be identical for all hypervisors.

When creating a hypervisor, you can choose to make it a pure hypervisor, a pure disk operations one or a mixed one. This allows adding NAS storage servers as pure disk operations. This configuration makes disk handling faster, as IsardVDI uses direct storage and commands on the NAS.

For example, an infrastructure with several hypervisors and two NAS units clustered with Pacemaker can share storage over NFSv4 with good performance.

High availability/high performance technical documents

All IsardVDI knowledge and experience in high-performance and high-availability clusters (using Pacemaker, DRBD, disk enclosures, live migrations, etc.) is kept in the Multi-server infrastructure section of the manual.

This section of the manual contains videos about the live migration of storage and virtual desktops performed on the IsardVDI infrastructure: the virtual desktop is migrated from one hypervisor to another while at the same time the storage is migrated from one NAS to another, without the virtual desktop user noticing.

Hypervisor self-registration flow and VPN configuration

Understanding the process

This section explains how hypervisors automatically register with the IsardVDI system and establish secure network connectivity.

When a hypervisor container starts with the appropriate configuration, the following automated self-registration process takes place:

1. Hypervisor self-registration

graph TD
    A[Hypervisor starts with cfg environment] --> B[Hypervisor contacts IsardVDI API]
    B --> C[API registers/updates hypervisor in database]
    C --> D[Event triggers isard-vpn configuration update]
    D --> E[Hypervisor requests final configuration from API]
    E --> F[Hypervisor configures VPN according to tunneling mode]
    F --> G[Hypervisor performs self-checks]
    G --> H[Hypervisor self-enables in database]
    H --> I[isard-engine connects via SSH for verification]
    I --> J[Engine sets final hypervisor status]

Step-by-step process:

  1. API registration: The hypervisor contacts the IsardVDI API with its configuration environment variables.
  2. Database update: The API creates or updates the hypervisor entry in the IsardVDI database with configuration parameters.
  3. VPN event trigger: The database change triggers an event on isard-vpn to update the hypervisor's network configuration.
  4. Configuration retrieval: The hypervisor requests its final configuration from the API (WireGuard keys, network configuration, etc.).

2. VPN tunnel establishment

The VPN configuration process differs depending on the configured tunneling mode:

WireGuard + Geneve mode

# 1. isard-vpn generates the WireGuard configuration
# 2. The hypervisor receives the WireGuard peer configuration via the API
# 3. WireGuard tunnel established (4443/UDP by default)
# 4. Geneve overlay network created over the WireGuard tunnel
# 5. OVS bridges configured for virtual machine networks

Configuration flow:

  • The isard-vpn container generates unique WireGuard keys for the hypervisor.
  • The hypervisor receives the configuration via IsardVDI API calls.
  • The WireGuard interface is created (wg0 on the hypervisor, hypers on isard-vpn).
  • Geneve tunnels are created over the encrypted WireGuard connection.
  • Open vSwitch ports are created and flow rules are configured.

Geneve only mode

# 1. The hypervisor resolves the IsardVDI server hostname/IP
# 2. Direct Geneve tunnel established (6081/UDP)
# 3. OVS bridges and ports configured
# 4. Redis connection established for storage operations (6379/TCP)

Configuration flow:

  • The hypervisor connects directly to the IP of the isard-vpn container (172.31.255.23:6081).
  • The Geneve tunnel interface is created without an encryption layer.
  • OVS ports and flow rules are configured for direct networking.
  • Storage operations connect directly to isard-redis (172.31.255.12:6379).

3. Network interface configuration

OVS bridge configuration:

# Automatic bridge creation (/src/ovs/setup.sh)
ovs-vsctl add-br ovsbr0
# Geneve tunnel port towards isard-vpn (WireGuard + Geneve mode)
ovs-vsctl add-port ovsbr0 <port> -- set interface <port> type=geneve options:remote_ip=<tunnel IP>

Key network components:

  • ovsbr0: Main OVS bridge where the virtual machines are connected.
  • geneve type ports: Tunnels towards isard-vpn for the overlay networks.
  • Flow rules: Automatically configured according to each virtual desktop's requirements.
  • VLAN support: Automatic detection and configuration of VLANs if trunk interfaces are configured.

4. Certificates and security

Automatic certificate management:

  • Viewer certificates downloaded from the IsardVDI server.
  • TLS certificates for secure hypervisor communication.
  • Certificate validation and renewal processes.

5. Service initialization

Container services started:

  • isard-hypervisor: Main hypervisor management service.
  • isard-storage: Storage operations (if enabled for mixed/storage hypervisors).
  • Video broker services (for hypervisor-standalone deployments).

6. Health monitoring and maintenance

Continuous processes:

  • Regular health checks via SSH from isard-engine.
  • Certificate renewal and updates.
  • VPN tunnel monitoring and automatic reconnection.
  • OVS flow rule updates according to the virtual desktop lifecycle.

Common troubleshooting

Connection errors: - Verify SSH key authentication between isard-engine and the hypervisor. - Check that firewall rules allow the required ports (2022/TCP, 4443/UDP or 6081/UDP). - Ensure proper DNS resolution between the hypervisor and the IsardVDI server.

VPN tunnel issues: - Check the isard-vpn container logs for WireGuard/Geneve errors. - Verify that the container's IP forwarding rules are correctly configured. - Confirm that the DOCKER_NET environment matches the actual container IPs.

OVS configuration issues: - Check for duplicate port creation errors in the hypervisor logs. - Verify proper assignment of the interface ofport. - Ensure there are no conflicting network configurations.

Following the configuration process

Useful commands to follow it:

# Check hypervisor connection status
docker logs isard-engine | grep <hypervisor_hostname>

# Monitor VPN tunnel establishment
docker logs isard-vpn | grep -E "(peer|tunnel|geneve)"

# Verify OVS configuration
docker exec isard-hypervisor ovs-vsctl show

# Check active WireGuard connections (if using WireGuard mode)
docker exec isard-vpn wg show

Hypervisor pools

On the same page, the Hypervisors pools list panel shows the hypervisor pools and, when one is expanded, its paths, interfaces and viewers. It is described in Hypervisor pools.

GPU

The GPUs panel of this page gathers the hypervisors' graphics cards. Their management (profiles, variants and delegated category) is in vGPUs, and the complete walkthrough to enable, plan, share and use a profile is in GPU setup.