Clúster activo-activo¶
Esta configuración usa dos servidores (hypervisor01 y hypervisor02) con hardware y software similares. Emplea RAID por software, DRBD 8 con doble primario, control de clúster con Pacemaker y el sistema de archivos de clúster GFS2. El sistema operativo es Fedora 22.
Red¶
Renombrar las interfaces
new_name=lan;
old_name=enp3s0;
echo SUBSYSTEM==\"net\", ACTION==\"add\", DRIVERS==\"?*\", \
ATTR{address}==\"$(cat /sys/class/net/$old_name/address)\", \
ATTR{type}==\"1\", KERNEL==\"e*\", \
NAME=\"$new_name\" >> /etc/udev/rules.d/70-persistent-net.rules
new_name=drbd;
old_name=enp1s0;
echo SUBSYSTEM==\"net\", ACTION==\"add\", DRIVERS==\"?*\", \
ATTR{address}==\"$(cat /sys/class/net/$old_name/address)\", \
ATTR{type}==\"1\", KERNEL==\"e*\", \
NAME=\"$new_name\" >> /etc/udev/rules.d/70-persistent-net.rules
new_name=dual0;
old_name=enp2s0f0;
echo SUBSYSTEM==\"net\", ACTION==\"add\", DRIVERS==\"?*\", \
ATTR{address}==\"$(cat /sys/class/net/$old_name/address)\", \
ATTR{type}==\"1\", KERNEL==\"e*\", \
NAME=\"$new_name\" >> /etc/udev/rules.d/70-persistent-net.rules
new_name=dual1;
old_name=enp2s0f1;
echo SUBSYSTEM==\"net\", ACTION==\"add\", DRIVERS==\"?*\", \
ATTR{address}==\"$(cat /sys/class/net/$old_name/address)\", \
ATTR{type}==\"1\", KERNEL==\"e*\", \
NAME=\"$new_name\" >> /etc/udev/rules.d/70-persistent-net.rules
Configuración de las interfaces de red
[root@hypervisor01 ~]# cat /etc/sysconfig/network-scripts/ifcfg-lan
TYPE="Ethernet"
BOOTPROTO="none"
DEFROUTE="yes"
IPV4_FAILURE_FATAL="no"
IPV6INIT="no"
IPV6_AUTOCONF="no"
IPV6_DEFROUTE="no"
IPV6_FAILURE_FATAL="no"
ONBOOT="yes"
PEERDNS="yes"
PEERROUTES="yes"
IPV6_PEERDNS="no"
IPV6_PEERROUTES="no"
NAME="lan"
IPADDR="192.0.2.24"
PREFIX="24"
GATEWAY="192.0.2.199"
DNS1="192.0.2.200"
DNS2="192.0.2.201"
DOMAIN="example.com"
[root@hypervisor02 ~]# cat /etc/sysconfig/network-scripts/ifcfg-lan
TYPE="Ethernet"
BOOTPROTO="none"
DEFROUTE="yes"
IPV4_FAILURE_FATAL="no"
IPV6INIT="no"
IPV6_AUTOCONF="no"
IPV6_DEFROUTE="no"
IPV6_FAILURE_FATAL="no"
ONBOOT="yes"
PEERDNS="yes"
PEERROUTES="yes"
IPV6_PEERDNS="no"
IPV6_PEERROUTES="no"
NAME="lan"
IPADDR="192.0.2.25"
PREFIX="24"
GATEWAY="192.0.2.199"
DNS1="192.0.2.200"
DNS2="192.0.2.201"
DOMAIN="example.com"
[root@hypervisor01 ~]# cat /etc/sysconfig/network-scripts/ifcfg-drbd
TYPE="Ethernet"
BOOTPROTO="none"
DEFROUTE="no"
IPV4_FAILURE_FATAL="no"
IPV6INIT="no"
IPV6_AUTOCONF="no"
IPV6_DEFROUTE="no"
IPV6_FAILURE_FATAL="no"
ONBOOT="yes"
PEERDNS="no"
PEERROUTES="no"
IPV6_PEERDNS="no"
IPV6_PEERROUTES="no"
NAME="drbd"
IPADDR="203.0.113.24"
PREFIX="24"
MTU="9000"
[root@hypervisor02 ~]# cat /etc/sysconfig/network-scripts/ifcfg-drbd
TYPE="Ethernet"
BOOTPROTO="none"
DEFROUTE="no"
IPV4_FAILURE_FATAL="no"
IPV6INIT="no"
IPV6_AUTOCONF="no"
IPV6_DEFROUTE="no"
IPV6_FAILURE_FATAL="no"
ONBOOT="yes"
PEERDNS="no"
PEERROUTES="no"
IPV6_PEERDNS="no"Tuneando fedora
IPV6_PEERROUTES="no"
NAME="drbd"
IPADDR="203.0.113.25"
PREFIX="24"
MTU="9000"
Particionado y RAID¶
- 1 SSD para el sistema operativo
- 1 SSD Intel de gama alta (100 GB) para usar como caché
- 3 discos duros (de 500 GB cada uno) en RAID 1
Formatear los discos y crear las particiones
parted -a optimal -s /dev/sda mklabel msdos
parted -a optimal -s /dev/sdc mklabel msdos
parted -a optimal -s /dev/sdd mklabel msdos
parted -a optimal -s /dev/sde mklabel msdos
[root@hypervisor01 ~]# lsblk
NAME MAJ:MIN RM SIZE RO TYPE MOUNTPOINT
sda 8:0 0 93,2G 0 disk
sdb 8:16 0 55,9G 0 disk
├─sdb1 8:17 0 500M 0 part /boot
├─sdb2 8:18 0 5,6G 0 part [SWAP]
├─sdb3 8:19 0 33,5G 0 part /
├─sdb4 8:20 0 1K 0 part
└─sdb5 8:21 0 16,4G 0 part /home
sdc 8:32 0 931,5G 0 disk
sdd 8:48 0 931,5G 0 disk
sde 8:64 0 931,5G 0 disk
[root@hypervisor01 ~]# parted -s /dev/sdc print
Model: ATA TOSHIBA DT01ACA0 (scsi)
Disk /dev/sdc: 500GB
Sector size (logical/physical): 512B/4096B
Partition Table: msdos
Disk Flags:
Number Start End Size Type File system Flags
1 1049kB 500GB 500GB primary raid
Ajustar los parámetros de los discos SSD¶
Desactivar el swap y evitar que se actualicen los tiempos de acceso (noatime):
Actualizar el archivo fstab:
Crear el RAID 1¶
mdadm --create /dev/md0 --level=mirror --raid-devices=2 /dev/sdc1 /dev/sdd1 --spare-devices=1 /dev/sde1
cat /proc/mdstat
Crear la caché LVM (sobre el RAID)¶
Volúmenes¶
Caché¶
vgextend vg_data /dev/sdb1
lvcreate -L 2G -n lv_cache_meta vg_data /dev/sdb1
lvcreate -L 88G -n lv_cache_data vg_data /dev/sdb1
lvcreate -l 100%FREE -n lv_data vg_data /dev/md0
lvconvert --yes --type cache-pool --cachemode writeback --poolmetadata vg_data/lv_cache_meta vg_data/lv_cache_data
lvconvert --type cache --cachepool vg_data/lv_cache_data vg_data/lv_data
lsblk
lvdisplay
lvdisplay -a
Ajustes de Fedora¶
Cortafuegos¶
SELinux¶
setenforce 0
sed -i s/SELINUX=enforcing/SELINUX=permissive/ /etc/sysconfig/selinux
sed -i s/SELINUX=enforcing/SELINUX=permissive/ /etc/selinux/config
sestatus
Utilidades¶
Protocolo de tiempo de red (NTP)¶
Ajustes del historial de Bash¶
cat >> .bashrc << "EOF"
# bash_history infinite
export HISTFILESIZE=
export HISTSIZE=
export HISTTIMEFORMAT="[%F %T] "
# Avoid duplicates
export HISTCONTROL=ignoredups:erasedups
# When the shell exits, append to the history file instead of overwriting it
shopt -s histappend
# After each command, append to the history file and reread it
export PROMPT_COMMAND="${PROMPT_COMMAND:+$PROMPT_COMMAND$'\n'}history -a; history -c; history -r"
alias history_cleaned="cat .bash_history |grep -a -v ^'#'"
export TMOUT=3600
EOF
DRBD 8¶
Instalar los paquetes¶
Archivos de configuración¶
Obtener los archivos de configuración de ejemplo de los paquetes instalados:
cp -a /etc/drbd.conf /root/drbd.conf.dist.f22
cp -a /etc/drbd.d/global_common.conf /root/drbd_global_common.conf.dist.f22
Configurar drbd.conf:
global {
usage-count yes;
}
common {
handlers {
}
startup {
}
options {
}
disk {
}
net {
protocol C;
allow-two-primaries;
after-sb-0pri discard-zero-changes;
after-sb-1pri discard-secondary;
after-sb-2pri disconnect;
}
}
Definir los recursos en /etc/drbd.d/vdisks.res:
resource vdisks {
device /dev/drbd0;
disk /dev/vg_data/lv_data;
meta-disk internal;
on hypervisor01 {
address 203.0.113.24:7789;
}
on hypervisor02 {
address 203.0.113.25:7789;
}
}
Crear los metadatos de DRBD:
drbdadm create-md vdisks
[...]
Writing meta data...
New drbd meta data block successfully created.
success
Hacer un ajuste de prueba (dry-run) para validar los archivos de configuración:
Aplicar la configuración:
Comprobar el estado en los dos servidores:
[root@hypervisor01 ~]# cat /proc/drbd
version: 8.4.5 (api:1/proto:86-101)
srcversion: 5A4F43804B37BB28FCB1F47
0: cs:Connected ro:Secondary/Secondary ds:Inconsistent/Inconsistent C r-----
ns:0 nr:0 dw:0 dr:0 al:0 bm:0 lo:0 pe:0 ua:0 ap:0 ep:1 wo:f oos:488236452
Forzar el rol primario en un servidor (hypervisor01):
Repetir el proceso en el otro servidor (hypervisor02) para tener una configuración de doble primario:
drbdadm primary vdisks
[root@hypervisor01 ~]# cat /proc/drbd
version: 8.4.5 (api:1/proto:86-101)
srcversion: 5A4F43804B37BB28FCB1F47
0: cs:SyncSource ro:Primary/Primary ds:UpToDate/Inconsistent C r-----
ns:17322104 nr:0 dw:0 dr:17323016 al:0 bm:0 lo:2 pe:2 ua:2 ap:0 ep:1 wo:f oos:470916516
[>....................] sync'ed: 3.6% (459876/476792)M
finish: 3:03:06 speed: 42,844 (36,616) K/sec
Clúster¶
Instalar los paquetes de Pacemaker¶
Agentes de fencing
Pacemaker
Recurso DRBD de Pacemaker
Paquetes necesarios para el sistema de archivos GFS2 (requiere control de bloqueo de clúster)
Iniciar y configurar el clúster¶
Configurar la resolución de nombres de host en /etc/hosts.
hypervisor01:
echo "hypervisor01" > /etc/hostname
echo "192.0.2.24 hypervisor01" >> /etc/hosts
echo "192.0.2.25 hypervisor02" >> /etc/hosts
exit
hypervisor02:
echo "192.0.2.24 hypervisor01" >> /etc/hosts
echo "192.0.2.25 hypervisor02" >> /etc/hosts
echo "hypervisor02" > /etc/hostname
exit
Los pasos siguientes se hacen en un solo nodo:
server1=hypervisor01
server2=hypervisor02
cl_name=hvcluster
pcs cluster auth $server1 $server2
pcs cluster setup --name $cl_name $server1 $server2
pcs cluster start --all
pcs status
[root@hypervisor01 ~]# pcs status
Cluster name: hvcluster
WARNING: no stonith devices and stonith-enabled is not false
WARNING: corosync and pacemaker node names do not match (IPs used in setup?)
Last updated: Sun Oct 25 23:37:34 2015 Last change:
Stack: unknown
Current DC: NONE
0 nodes and 0 resources configured
Full list of resources:
PCSD Status:
hypervisor01 member (hypervisor01): Online
hypervisor02 member (hypervisor02): Online
Daemon Status:
corosync: active/disabled
pacemaker: active/disabled
pcsd: active/enabled
Comprobar que la configuración del clúster se carga como se espera.
[root@hypervisor01 ~]# pcs cluster cib |grep hypervisor
<cib crm_feature_set="3.0.10" validate-with="pacemaker-2.3" epoch="5" num_updates="8" admin_epoch="0" cib-last-written="Sun Oct 25 23:52:24 2015" update-origin="hypervisor02" update-client="crmd" update-user="hacluster" have-quorum="1" dc-uuid="2">
<nvpair id="cib-bootstrap-options-cluster-name" name="cluster-name" value="hvcluster"/>
<node id="1" uname="hypervisor01"/>
<node id="2" uname="hypervisor02"/>
<node_state id="2" uname="hypervisor02" in_ccm="true" crmd="online" crm-debug-origin="do_state_transition" join="member" expected="member">
<node_state id="1" uname="hypervisor01" in_ccm="true" crmd="online" crm-debug-origin="do_state_transition" join="member" expected="member">
[root@hypervisor01 ~]# grep hypervisor /etc/corosync/corosync.conf
cluster_name: hvcluster
ring0_addr: hypervisor01
ring0_addr: hypervisor02
Fencing¶
[root@hypervisor01 ~]# pcs stonith list
fence_apc - Fence agent for APC over telnet/ssh
fence_apc_snmp - Fence agent for APC, Tripplite PDU over SNMP
Comprobar que el dispositivo STONITH es accesible y funciona:
fence_apc_snmp --ip=stonith1 --action=monitor
fence_apc_snmp --ip=stonith1 --action=monitor --community=<community>
fence_apc_snmp --ip=stonith1 --action=reboot --plug=6 --community=<community> --power-wait=5
Configurar el recurso STONITH por SSH (descartado porque es demasiado lento):
#pwd1=$(cat /root/pwd1)
#pwd2=$(cat /root/pwd2)
pcs stonith delete stonith1
pcs cluster cib stonith_cfg
pcs -f stonith_cfg stonith create stonith1 fence_apc ipaddr=192.0.2.3 login=<user> passwd=$pwd1 pcmk_host_list="hypervisor01 hypervisor02" pcmk_host_map="hypervisor01:4;hypervisor02:5"
#pcs -f stonith_cfg stonith create stonith2 fence_apc ipaddr=192.0.2.3 login=<user> passwd=$pwd2 pcmk_host_list="hypervisor02" pcmk_host_map="hypervisor02:3"
pcs -f stonith_cfg property set stonith-enabled=false
pcs cluster cib-push stonith_cfg
Configurar el recurso STONITH por SNMP (el que se usa en esta configuración):
pcs stonith delete stonith1
pcs cluster cib stonith_cfg
pcs -f stonith_cfg stonith create stonith1 fence_apc_snmp params ipaddr=192.0.2.3 pcmk_host_list="hypervisor01,hypervisor02" pcmk_host_map="hypervisor01:4;hypervisor02:5" pcmk_host_check=static-list power_wait=5
pcs cluster cib-push stonith_cfg
Activar el recurso STONITH:
Hacer pruebas (atención: ¡reinicia los nodos!):
El fencing se puede desactivar mientras se configura el clúster:
Comprobar la definición del recurso STONITH:
Los registros están en:
PACEMAKER DRBD¶
echo drbd > /etc/modules-load.d/drbd.conf
pcs resource create drbd-vdisks ocf:linbit:drbd drbd_resource=vdisks op monitor interval=60s
pcs resource master drbd-vdisks-clone drbd-opt master-max=2 master-node-max=1 clone-max=2 clone-node-max=1 notify=true
dlm¶
El sistema de archivos GFS2 necesita bloqueo de clúster.
pcs cluster cib dlm_cfg
pcs -f dlm_cfg resource create dlm ocf:pacemaker:controld op monitor interval=60s
pcs -f dlm_cfg resource clone dlm clone-max=2 clone-node-max=1
pcs cluster cib-push dlm_cfg
LVM de clúster¶
Configurar los LVM de clúster¶
systemctl disable lvm2-lvmetad.service
systemctl disable lvm2-lvmetad.socket
systemctl stop lvm2-lvmetad.service
lvmconf --enable-cluster
reboot
Definir los dispositivos donde LVM busca firmas LVM en el archivo /etc/lvm/lvm.conf:
Configurar los LVM con bloqueo de clúster¶
pcs cluster cib clvmd_cfg
pcs -f clvmd_cfg resource create clvmd ocf:heartbeat:clvm params daemon_options="timeout=30s" op monitor interval=60s
pcs -f clvmd_cfg resource clone clvmd clone-max=2 clone-node-max=1
pcs cluster cib-push clvmd_cfg
Comprobar el estado del clúster:
[root@hypervisor02 ~]# pcs status
Cluster name: hvcluster
WARNING: corosync and pacemaker node names do not match (IPs used in setup?)
Last updated: Thu Oct 29 13:14:58 2015 Last change: Thu Oct 29 13:14:42 2015 by root via cibadmin on hypervisor02
Stack: corosync
Current DC: hypervisor02 (version 1.1.13-3.fc22-44eb2dd) - partition with quorum
2 nodes and 7 resources configured
Online: [ hypervisor01 hypervisor02 ]
Full list of resources:
Master/Slave Set: drbd-vdisks-clone [drbd-vdisks]
Masters: [ hypervisor01 hypervisor02 ]
stonith1 (stonith:fence_apc_snmp): Started hypervisor01
Clone Set: dlm-clone [dlm]
Started: [ hypervisor01 hypervisor02 ]
Clone Set: clvmd-clone [clvmd]
Started: [ hypervisor01 hypervisor02 ]
PCSD Status:
hypervisor01 member (hypervisor01): Online
hypervisor02 member (hypervisor02): Online
Daemon Status:
corosync: active/enabled
pacemaker: active/enabled
pcsd: active/enabled
Crear los volúmenes¶
En cada servidor:
Para las acciones de clúster se usa la opción -c:
Ahora se puede continuar con las órdenes de todo el clúster:
Comprobar en el otro nodo que se ha creado el grupo de volúmenes:
[root@hypervisor02 ~]# vgs
VG #PV #LV #SN Attr VSize VFree
vg_data 2 1 0 wz--n- 558,79g 1,16g
vgcluster 1 0 0 wz--nc 465,62g 465,62g
Se deja algo de espacio libre por si se quieren hacer pruebas de E/S:
Comprobarlo desde el otro servidor:
[root@hypervisor01 ~]# lvs
LV VG Attr LSize Pool Origin Data% Meta% Move Log Cpy%Sync Convert
lv_data vg_data Cwi-aoC--- 465,63g [lv_cache_data] [lv_data_corig] 0,00 0,82 0,00
lvcluster1 vgcluster -wi-a----- 451,65g
Ejecutar el fencing desde DRBD¶
Añadir lo siguiente a la sección handlers de /etc/drbd.d/global_common.conf:
fence-peer "/usr/lib/drbd/crm-fence-peer.sh";
after-resync-target "/usr/lib/drbd/crm-unfence-peer.sh";
Añadir lo siguiente a la sección disk:
El resultado es:
[root@hypervisor01 ~]# cat /etc/drbd.d/global_common.conf
global {
usage-count yes;
}
common {
handlers {
split-brain "/usr/lib/drbd/notify-split-brain.sh root";
fence-peer "/usr/lib/drbd/crm-fence-peer.sh";
after-resync-target "/usr/lib/drbd/crm-unfence-peer.sh";
}
startup {
}
options {
}
disk {
fencing resource-and-stonith;
}
net {
protocol C;
allow-two-primaries;
after-sb-0pri discard-zero-changes;
after-sb-1pri discard-secondary;
after-sb-2pri disconnect;
}
}
Comprobar que Pacemaker y STONITH funcionan:
[root@hypervisor01 ~]# pcs property list
Cluster Properties:
cluster-infrastructure: corosync
cluster-name: hvcluster
dc-version: 1.1.13-3.fc22-44eb2dd
have-watchdog: false
stonith-enabled: true
Confirmar que STONITH está activado:
Restricciones¶
dlm y clvmd se inician en este orden:
pcs cluster cib constraints_cfg
pcs constraint order set drbd-vdisks-clone action=promote \
set dlm-clone clvmd-clone action=start \
sequential=true
pcs cluster cib-push constraints_cfg
DRBD¶
Ejemplo de configuración de DRBD para un clúster GFS2.
Crear los recursos DRBD en /etc/drbd.d/.
drbdadm create-md bases
drbdadm create-md templates
drbdadm create-dm grups
drbdadm up bases
drbdadm up templates
drbdadm up grups
drbdadm primary bases --force
drbdadm primary templates --force
drbdadm primary grups --force
Recursos dlm y clvm2¶
LVM de clúster
pcs cluster cib locks_cfg
pcs -f locks_cfg resource create dlm ocf:pacemaker:controld op monitor interval=60s --group cluster_lock
pcs -f locks_cfg resource create clvmd ocf:heartbeat:clvm params daemon_options="timeout=30s" op monitor interval=60s --group cluster_lock
pcs -f locks_cfg resource clone cluster_lock clone-max=2 clone-node-max=1 on-fail=restart
pcs cluster cib-push locks_cfg
LVM sin clúster
pcs resource create dlm ocf:pacemaker:controld op monitor interval=60s
pcs resource clone dlm clone-max=2 clone-node-max=1 on-fail=restart
Recursos DRBD¶
pcs cluster cib drbd_bases_cfg
pcs -f drbd_bases_cfg resource create drbd_bases ocf:linbit:drbd drbd_resource=bases op monitor interval=60s
pcs -f drbd_bases_cfg resource master drbd_bases-clone drbd_bases master-max=2 master-node-max=1 clone-max=2 clone-node-max=1 notify=true
pcs cluster cib-push drbd_bases_cfg
pcs cluster cib drbd_templates_cfg
pcs -f drbd_templates_cfg resource create drbd_templates ocf:linbit:drbd drbd_resource=templates op monitor interval=60s
pcs -f drbd_templates_cfg resource master drbd_templates-clone drbd_templates master-max=2 master-node-max=1 clone-max=2 clone-node-max=1 notify=true
pcs cluster cib-push drbd_templates_cfg
pcs cluster cib drbd_grups_cfg
pcs -f drbd_grups_cfg resource create drbd_grups ocf:linbit:drbd drbd_resource=grups op monitor interval=60s
pcs -f drbd_grups_cfg resource master drbd_grups-clone drbd_grups master-max=2 master-node-max=1 clone-max=2 clone-node-max=1 notify=true
pcs cluster cib-push drbd_grups_cfg
Sistema de archivos GFS2¶
mkfs.gfs2 -p lock_dlm -t hvcluster:bases -j 2 /dev/drbd10
mkfs.gfs2 -p lock_dlm -t hvcluster:templates -j 2 /dev/drbd11
mkfs.gfs2 -p lock_dlm -t hvcluster:grups -j 2 /dev/drbd30
Recursos GFS2¶
pcs resource create gfs2_bases Filesystem device="/dev/drbd10" directory="/isard/bases" fstype="gfs2" "options=defaults,noatime,nodiratime,noquota" op monitor interval=10s on-fail=restart clone clone-max=2 clone-node-max=1
pcs resource create gfs2_templates Filesystem device="/dev/drbd11" directory="/isard/templates" fstype="gfs2" "options=defaults,noatime,nodiratime,noquota" op monitor interval=10s on-fail=restart clone clone-max=2 clone-node-max=1
pcs resource create gfs2_grups Filesystem device="/dev/drbd30" directory="/isard/grups" fstype="gfs2" "options=defaults,noatime,nodiratime,noquota" op monitor interval=10s on-fail=restart clone clone-max=2 clone-node-max=1
Servidor NFS 4¶
pcs cluster cib nfsserver_cfg
pcs -f nfsserver_cfg resource create nfs-daemon systemd:nfs-server \
nfs_shared_infodir=/nfsshare/nfsinfo nfs_no_notify=true \
--group nfs_server
pcs -f nfsserver_cfg resource create nfs-root exportfs \
clientspec=192.0.2.0/255.255.255.0 \
options=rw,async,wdelay,no_root_squash,no_subtree_check,sec=sys,rw,secure,no_root_squash,no_all_squash \
directory=/isard \
fsid=0 \
--group nfs_server
pcs cluster cib-push nfsserver_cfg
pcs resource clone nfs_server master-max=2 master-node-max=1 clone-max=2 clone-node-max=1 on-fail=restart notify=true resource-stickiness=0
Exportaciones NFS 4¶
pcs cluster cib exports_cfg
pcs -f exports_cfg resource create nfs_bases exportfs \
clientspec=192.0.2.0/255.255.255.0 \
options=rw,async,wdelay,no_root_squash,no_subtree_check,sec=sys,rw,secure,no_root_squash,no_all_squash directory=/isard/bases \
fsid=11 \
clone master-max=2 master-node-max=1 clone-max=2 clone-node-max=1 on-fail=restart notify=true resource-stickiness=0
pcs -f exports_cfg resource create nfs_templates exportfs \
clientspec=192.0.2.0/255.255.255.0 \
options=rw,async,wdelay,no_root_squash,no_subtree_check,sec=sys,rw,secure,no_root_squash,no_all_squash directory=/isard/templates \
fsid=21 \
clone master-max=2 master-node-max=1 clone-max=2 clone-node-max=1 on-fail=restart notify=true resource-stickiness=0
pcs -f exports_cfg resource create nfs_grups exportfs \
clientspec=192.0.2.0/255.255.255.0 \
options=rw,async,wdelay,no_root_squash,no_subtree_check,sec=sys,rw,secure,no_root_squash,no_all_squash directory=/isard/grups \
fsid=31 \
clone master-max=2 master-node-max=1 clone-max=2 clone-node-max=1 on-fail=restart notify=true resource-stickiness=0
pcs cluster cib-push exports_cfg
IP flotantes¶
pcs resource create ClusterIPbases ocf:heartbeat:IPaddr2 ip=198.51.100.210 cidr_netmask=32 nic=nas:10 clusterip_hash=sourceip-sourceport-destport meta resource-stickiness=0 op monitor interval=5 clone globally-unique=true clone-max=2 clone-node-max=2 on-fail=restart resource-stickiness=0
pcs resource create ClusterIPtemplates ocf:heartbeat:IPaddr2 ip=198.51.100.211 cidr_netmask=32 nic=nas:11 clusterip_hash=sourceip-sourceport-destport meta resource-stickiness=0 op monitor interval=5 clone globally-unique=true clone-max=2 clone-node-max=2 on-fail=restart resource-stickiness=0
pcs resource create ClusterIPgrups ocf:heartbeat:IPaddr2 ip=198.51.100.212 cidr_netmask=32 nic=nas:30 clusterip_hash=sourceip-sourceport-destport meta resource-stickiness=0 op monitor interval=5 clone globally-unique=true clone-max=2 clone-node-max=2 on-fail=restart resource-stickiness=0
pcs resource create ClusterIPcnasbases ocf:heartbeat:IPaddr2 ip=192.0.2.28 cidr_netmask=32 nic=nas:110 clusterip_hash=sourceip-sourceport-destport meta resource-stickiness=0 op monitor interval=5 clone globally-unique=true clone-max=2 clone-node-max=2 on-fail=restart resource-stickiness=0
pcs resource create ClusterIPcnastemplates ocf:heartbeat:IPaddr2 ip=192.0.2.29 cidr_netmask=32 nic=nas:111 clusterip_hash=sourceip-sourceport-destport meta resource-stickiness=0 op monitor interval=5 clone globally-unique=true clone-max=2 clone-node-max=2 on-fail=restart resource-stickiness=0
pcs resource create ClusterIPcnasgrups ocf:heartbeat:IPaddr2 ip=192.0.2.30 cidr_netmask=32 nic=nas:130 clusterip_hash=sourceip-sourceport-destport meta resource-stickiness=0 op monitor interval=5 clone globally-unique=true clone-max=2 clone-node-max=2 on-fail=restart resource-stickiness=0
Restricciones¶
Orden de arranque y parada, y restricciones
pcs constraint order \
set stonith action=start \
set cluster_lock-clone action=start \
set nfs_server-clone action=start \
require-all=true sequential=true \
setoptions kind=Mandatory id=serveis
pcs constraint order \
set drbd_bases-clone action=promote role=Master \
set gfs2_bases-clone \
set nfs_bases-clone \
set ClusterIPcnasbases-clone action=start \
set ClusterIPbases-clone action=start \
require-all=true sequential=true \
setoptions kind=Mandatory id=bases
pcs constraint order \
set drbd_templates-clone action=promote role=Master \
set gfs2_templates-clone \
set nfs_templates-clone \
set ClusterIPcnastemplates-clone action=start \
set ClusterIPtemplates-clone action=start \
require-all=true sequential=true \
setoptions kind=Mandatory id=templates
pcs constraint order \
set drbd_grups-clone action=promote role=Master \
set gfs2_grups-clone \
set nfs_grups-clone \
set ClusterIPcnasgrups-clone action=start \
set ClusterIPgrups-clone action=start \
require-all=true sequential=true \
setoptions kind=Mandatory id=grups
Restricciones de ubicación
pcs constraint colocation add \
ClusterIPbases-clone with nfs_bases-clone INFINITY \
id=colocate_bases
pcs constraint colocation add \
ClusterIPtemplates-clone with nfs_templates-clone INFINITY \
id=colocate_templates
pcs constraint colocation add \
ClusterIPgrups-clone with nfs_grups-clone INFINITY \
id=colocate_grups
pcs constraint colocation add \
ClusterIPcnasbases-clone with nfs_bases-clone INFINITY \
id=colocate_cnasbases
pcs constraint colocation add \
ClusterIPcnastemplates-clone with nfs_templates-clone INFINITY \
id=colocate_cnastemplates
pcs constraint colocation add \
ClusterIPcnasgrups-clone with nfs_grups-clone INFINITY \
id=colocate_cnasgrups